N1201SA UV RF Vector Impedance ANT SWR Antenna Analyzer Meter Tester 140MHz – 2.7GHz

Product Id: 230361
Sold: 88
8sold in last 24 hours

Quantity Remaining:

Hurry! Only11Left.

Price: $198.26

Sale: $138.59

You Save: $59.67 (30%)

In Stock
Sold Out
Order processing within 1-3 business days. Estimated delivery between Sat. 28. Sep and Thu. 10. Oct

Depends on the product properties you select

Payment

Return Policy

You can return it to us within 3 days after delivery or 30 days after shipment in case the delivery date is not traceableView More

Buyer Protection

  • Full Refund, if you don't receive your order
  • Full or Partial Refund, if the item is not as described

Description:

N1201SA series is the handheld radio frequency vector impedance measurement analysis instrument, easy to use, simple operation. Built-in high capacity lithium ion battery for mobile and outdoor use.
Shutdown automatically save settings parameter without human intervention, after starting up, interface settings completely the same as  the power off before, use very worry.
Can be used to test the antenna, the imppedance of the radio frequency devices.
As RF impedance measuring need calibration, so you need to purchae separately calibration.

Specification:
 

Working currency: 140MHz~2700MHz
Actual currency : 137.5~2700MHz
Stepped frequency: 1kHz
Display: 2.4″ TFT trdp
Resolution ratio: 320 x 240(QVGA)
Battery capacity: 2000mAH(7.4Wh)
Power consumption: <1.5W
Charge current: 400mA
Charge port: USB
Auto power off can be set 5-60minutes.
Measured parameters: Resistence, Reactance, Standing wave, S11
Resolution ratio: 4 number
Frequency accuracy: about 5ppm
Connector: SMA-K
 
Measurement range:
Impedance: 0.1~1000
Standing wave: 1.000~65
S11(dB): 0dB~-60dB
 
Working temperature: 0~40℃
Atmospheric pressure: 860hPa~1060hPa
 
This instrument  has  four interfaces: single point measurement, scanning, system information, correction and calibration
The default boot into single-point measurement interface.
Note: For the convenience of the user, each time calibration correction options will automatically change to the user calibration. Meanwhile, in order to ensure the integrity of the calibration, the calibration process, the automatic shutdown function fails, the consistent boot.
 
Startup and shutdown
Hold down the CTRL key off press the power switch button.
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down.
The boot state, long press (2S above) the switch button, after the release, the instrument will shut down.
 
Recommend the use
1. In order to ensure the accuracy of measurement and calibration, preheat the instrument at least 15 minutes.
2. Try to use good quality RF cable and connectors.
3. Calibrated cable marked to the next may not need to calibrate and direct use.
4. Test cable process affect the measurement accuracy, it is recommended that, where possible, do not choose too long test cable.
5. Measurement and calibration before, make sure you are not in a strong wireless signal, so as to avoid interference caused by inaccurate measurements.
6. If the impedance measurements themselves do not understand, you can refer to a vector network analyzer instructions and tutorials. This instrument is equivalent to a single-port vector network analysis.

>>>PLEASE CLICK HERE TO FIND MORE INFORMATION<<<

Package included:

1 x N1201SA  ANT SWR Antenna Analyzer(English Version)

Detail Pictures:

 

 

 

 

 

 

 

 

 
,,,,,,,,